INSTITUTIONAL|SEPTA CLEAN M
Septic tanks are widely used in rural areas where there is no sewage collection system and it is necessary to treat domestic wastewater. Untreated wastewater from the house or group of houses flows into the septic tank where the solids separate from the liquids. The majority of the solids settle to the bottom where they are liquefied slowly. Lighter solids such as grease, fats and soaps float to the surface and form the scum layer. The septic tank is designed to retain the solids in the tank. The liquid passes out of the septic tank and into a percolation system or soakaway.
The degradative activity in a septic tank is based on a natural anaerobic (oxygen -free) biological process. This activity helps to liquefy solids, digest paper and other fibres and breakdown fats and grease. The liquid waste flows to the soakaway where further degradation occurs.
BFL 5600SS
* Application of industrial wastewater.
* Degradation of all the main classes of compounds in surfactants like anionic, cationic, non-ionic and amphoteric.
* Degradation of the surfactants from different compounds and characteristics (such as soaps, wetting agents, emulsifiers, detergents, ect) to CO2 and H2O in an environmentally acceptable way.
* Treatment of excessive foaming.
* Poor COD / BOD removal.
* BFL 5600SS can be used in conjunction with BFL 5000 series products for multi-problems treatment at the same time for a specific application (once-through solutions) in a system depending on the nature of the wastewater being produced. Remember the rule of Golden ratios of BFL products.
* Microbes work under aerobic conditions and as facultative anaerobes.
MUNICIPAL|BFL 4900CS
* Application of municipal wastewater.
* Efficient degradation of a wide range of organic chemicals like phenols, solvents, amines, aromatics, aliphatic hydrocarbons, pharmaceutical intermediates, etc. in municipal plants.
* Aerobic degradation of chemicals and solvents in aerobic wastewater treatment systems.
BFL 4900CS can be used in conjunction with BFL 4000 series products for multi-problems treatment at the same time for a specific application (once-through solutions) in a system depending on the nature of the wastewater being produced. Remember the rule of Golden ratios of BFL products.
* Microbes work under aerobic conditions and as facultative anaerobes.
MUNICIPAL|BFL 4100FG
Outstanding advantages of the product:
* Application of municipal wastewater.
* Degradation of the vegetable oils, hydrogenated oils and organic matter to CO2 and H2O in a highly effective and environmentally acceptable way.
* Aerobic degradation of fats, oils and grease (FOG) in municipal plants.
* Nocardia foaming removal.
* Poor BOD removal.
* Microbes work under aerobic conditions and as facultative anaerobes.
HỆ THỐNG NƯỚC THẢI CÔNG NGHIỆP|BFL 5050BC
Đặc tính ưu việt của sản phẩm:
* Ứng dụng trong xử lý nước thải công nghiệp thực phẩm / nước thải tập trung của ngành công nghiệp sản xuất bơ, sữa và các ngành liên quan bơ, sữa.
* Phân mảnh các khuẩn lạc và tăng cưởng tạo bông.
* Loại bỏ bùn dư thừa, dầy đặc.
* Giảm đáng kể tổng chất lắng lơ lửng ở nước thải đầu ra.
* Loại bỏ BOD/COD kém ở nước thải đầu ra.
* Cung cấp chất dinh dưỡng và vi dinh dưỡng tăng cường sinh khối khỏe mạnh với đặc tính xử lý tốt.
* Vi sinh hoạt động ở điều kiện hiếu khí và kỵ khí tùy nghi.
INDUSTRIAL|BFL 5200VP
Outstanding advances of the product:
* Application of industrial food processing plants/industrial chemical plants.
* Degradation of starches, cellulose, hemicelluloses, sugars, vegetable protein and the organic matter to CO2 and H2O in highly effective and environmentally acceptable way.
* Odour control.
* BFL 5200VP can be used in conjunction with BFL 5000 series products for multi-problems treatment at the same time for a specific application (once-through solutions) in a system depending on the nature of the wastewater being produced. Remember the rule of Golden ratios of BFL products.
* Microbes work under aerobic conditions and as facultative anaerobes.
INDUSTRIAL|BFL 5050VF
Outstanding advantages of the product:
* Application of industrial wastewater.
* Efficient degradation of vegetable oil extraction industry such as palm oil, olive oil, rapeseed oil, etc. and other organic matter to CO2 and H2O in a highly effective and environmentally acceptable way.
* Nocardia foaming removal.
* Removing oil coat from drains, pumps, pumping stations, inlet screens and primary clarifiers.
* BFL 5050VF can be used in conjunction with BFL 5000 series products for multi-problems treatment at the same time for a specific application (once-through solutions) in a system depending on the nature of the wastewater being produced. Remember the rule of Golden ratios of BFL products.
* Microbes work under aerobic conditions and as facultative anaerobes.
MUNICIPAL|BFL 4600SO
Outstanding advantages of the product:
* Application of municipal wastewater.
* Oxidation of reduced sulphur compounds in sewers, pumps sumps, lagoons, sludge storage tanks, etc.
* In industrial wastewaters, alkalinity in excess of 50 mg/l expressed as CaCO3 can be required.
* Anoxic tank
* Bad odour removal.
* BFL 4600SO can be used in conjunction with BFL 4000 series products for multi-problems treatment at the same time for a specific application (once-through solutions) in a system depending on the nature of the wastewater being produced. Remember the rule of Golden ratios of BFL products.
* Microbes work under aerobic conditions and as facultative anaerobes.
MUNICIPAL|BFL 4400AN
Outstanding advantages of the product:
* Application of industrial/municipal wastewater in chemical or food processing plants (winery, brewery, rubber processing, ect.)
* Degradation of cellulose, amylase, protease, lipase proteins, carbohydrates and fats.
* Degradation of organic matter to organic acids and thus improving the conversion to methane in a highly effective and environmentally acceptable way.
* In food processing plants, use other BFL 5050BS product to remove Bulking sludge before starting a dosing programme using BFL 4400AN. Another case, if there is bad odour problems arising from H2S, therefore BFL 5700SO is required.
* In industrial chemical plants and other Industries, use BFL 4400AN for the anaerobic stage and then BFL 5200VP and BFL 5400GC for the aerobic stage. There can also be bad odour problems due to H2S so BFL 5700SO may be required.
* Microbes work under anaerobic conditions and as facultative aerobes.